首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Development of post-column enzymic reactors with immobilized alcohol oxidase for use in the high-performance liquid chromatographic assay of alcohols with electrochemical detection
Institution:1. Key Laboratory of Pollution Processes and Environmental Criteria (Ministry of Education), Tianjin Engineering Center of Environmental Diagnosis and Contamination Remediation, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China;2. Tianjin Key Laboratory of Clean Energy and pollution control, School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin 300401, China;3. Tianjin Eco-Environmental Comprehensive Support Center, Tianjin 300191, China;1. Grupo de Ecología de Sistemas Acuáticos a escala de Paisaje (GESAP) INIBIOMA, Universidad Nacional del Comahue, CONICET, Quintral 1250, San Carlos de Bariloche, 8400, Argentina
Abstract:The development of a very sensitive, direct injection high-performance liquid chromatographic method, using a post-column reactor with immobilized alcohol oxidase, was undertaken with the aim of determining methanol and ethanol levels in microlitre volumes of biological samples. After reversed-phase chromatography to separate methanol and ethanol, the analytes were enzymically converted into the respective aldehydes with formation of stoichiometric amounts of hydrogen peroxide, which could be measured via electrochemical oxidation at a platinum electrode. Some problems were encountered in the development of solid-phase enzymic reactors, using a delicate enzyme, that is prone to lose activity, such as alcohol oxidase. Owing to the slightly alkaline pH required for the optimum activity of alcohol oxidase, polymeric columns seemed to be preferable for the chromatography. HEMA copolymer was chosen as the stationary phase, but the methanol and ethanol peaks eluted close together and posed severe problems of limiting post-column band spreading. Reactors based on coarse supports for enzyme immobilization gave unacceptable band spreading, causing the methanol and ethanol peaks to overlap. On the other hand high-performance liquid chromatographic packings maintained the efficiency of the chromatographic separation, quite independently of the reactor volume. Polymeric supports proved superior to silicas in maintaining the enzyme activity. However, relevant changes in the enzyme substrate specificity were observed after immobilization.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号