首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Determination of free and total 7-hydroxycoumarin in urine and serum by capillary electrophoresis
Institution:1. School of Environmental and Safety Engineering, Changzhou University, Jiangsu 213164, China;2. College of Chemistry, Dalian University of Technology, Dalian 116024, China;3. College of Medical Laboratory, Dalian Medical University, Dalian 116044, China
Abstract:A new method for the rapid determination of 7-hydroxycoumarin, the predominant metabolite of coumarin in humans, was developed for analysis in urine and serum, based on separation by capillary electrophoresis, with UV detection at 210 nm. The linear detection range for 7-hydroxycoumarin was 0–50 μg/ml while the limit of quantitation was 1 μg/ml. An internal standard, 3-(α-acetonylbenzyl)-4-hydroxycoumarin, was utilised for the determination of free 7-hydroxycoumarin, but it was found not to be suitable in the analysis of total 7-hydroxycoumarin present. Urine from two volunteers, who had been administered coumarin, was analysed by both capillary electrophoresis and by HPLC. The results from the two methods were compared and contrasted. The CE method was found to decrease the analysis time in comparison to HPLC analysis, with results available after 1.5 min as compared to 12 min with HPLC. There was no statistical difference between the results determined by either method.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号