首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Complications of Absorbable Fixation in Maxillofacial Surgery: A Meta-Analysis
Authors:Liya Yang  Meibang Xu  Xiaolei Jin  Jiajie Xu  Jianjian Lu  Chao Zhang  Tian Tian  Li Teng
Institution:Department 2 of Cranio-maxillo-facial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, P.R. China.; Harvard Medical School, United States of America,
Abstract:

Background

The use of titanium during maxillofacial fixation is limited due to its palpability, mutagenic effects and interference with imaging, which lead to the requirement for subsequent removal. The use of a biologically absorbable fixation material will potentially eliminate these limitations. In this meta-analysis, we analyzed the complications of absorbable fixation in maxillofacial surgery.

Methods

We performed a systematic search of PubMed, Embase, Cochrane Central Register of Systematic Reviews and Cochrane Central Register of Controlled Trials for trials published through December 2012. Data extracted from literature were analyzed with Review manager 5.0.24.

Results

Relevant data was extracted from 20 studies (1673 participants) and revealed that patients in the absorbable group had significantly more complications than those in the titanium group (RR = 1.20; 95% CI: 1.02–1.42; P = 0.03) in all enrolled maxillofacial surgeries. For bimaxillary operation subgroup, the absorbable fixation group did not have a significant increase in complications when compared with the titanium group (RR = 1.89; 95% CI: 0.85–4.22; P = 0.12). There was no significant difference observed between the absorbable and titanium groups receiving a bilateral sagittal split ramus osteotomy (BSSRO) (RR = 1.45; 95% CI: 0.84–2.48; P = 0.18) and Le Fort I osteotomy (RR = 0.65; 95% CI: 0.34–1.23; P = 0.18). The combined results of the five trials revealed that the absorbable group had a significantly lower rate of complications compared to the titanium group (RR = 0.71; 95% CI: 0.52–0.97; P = 0.03) in fracture fixation.

Conclusion

This meta-analysis shows that absorbable fixation systems used for fixation in maxillofacial surgery do not have adequate safety profiles. Subgroup indicated the safety of absorbable fixation systems was superior during fracture fixation. The absorbable fixation systems tend to have a similar favorable safety profile as titanium fixation during Le Fort I, bimaxillary operation and BSSRO.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号