首页 | 本学科首页   官方微博 | 高级检索  
     


A nitromethane‐based HPLC system alternative to acetonitrile for carotenoid analysis of fruit and vegetables
Authors:Gerhard Sandmann
Affiliation:Molecular Biosciences 213, J.W. Goethe Universit?t, P.O. Box 111932, D‐60054 Frankfurt, Germany
Abstract:Acetonitrile‐based HPLC systems are the most commonly used for carotenoid analysis from different plant tissues. Because of the acetonitrile shortage, an HPLC system for the separation of carotenoids on C18 reversed‐phase columns was developed in which an acetonitrile–alcohol‐based mobile phase was replaced by nitromethane. This solvent comes closest to acetonitrile with respect to its elutrophic property. Our criterion was to obtain similar separation and retention times for a range of differently structured carotenoids. This was achieved by further increase in the lipophilicity with ethylacetate. For all the carotenoids which we tested, we found co‐elution only of β‐cryptoxanthin and lycopene. By addition of 1% of water, separation of this pair of carotenoids was also achieved. The final recommended mobile phase consisted of nitromethane : 2‐propanol : ethyl acetate : water (79 : 10 : 10 : 1, by volume). On Nucleosil C18 columns and related ones like Hypersil C18, we obtained separation of carotenes, hydroxyl, epoxy and keto derivatives, which resembles the excellent separation properties of acetonitrile‐based mobile phases on C18 reversed phase columns. We successfully applied the newly developed HPLC system to the separation of carotenoids from different vegetables and fruit. Copyright © 2010 John Wiley & Sons, Ltd.
Keywords:carotenoid analysis  fruit  HPLC  nitromethane  vegetables