首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of medrogestone in plasma by high-performance liquid chromatography
Authors:Wen-Jen Lin  Shu-Jiuan Her  Po-Fen Chen  Russel Rhei-Long Chen
Affiliation:School of Pharmacy, College of Medicine, National Taiwan University, F 12 NO. 1 Sec. 1 Ren Ai Rd., Taipei, Taiwan
Abstract:Interference with the UV absorbance of medrogestone by endogenous steroids in plasma was prevented by reacting plasma with oxalyl chloride. The reduction of interference was effective when oxalyl chloride was in the range 10–50 μl/ml plasma. Reaction of oxalyl chloride with plasma for 10 min could reduce interference approximately 5.5-fold, and there was no significant reduction after 30 min. The limit of quantitative concentration for medrogestone in HPLC was 1 ng/ml. The standard curves were linear with the correlation coefficient greater than 0.999 in the range of 1–30 ng/ml. The coefficients of variation of both intra- and inter-day mean values were <12% and <10% of the actual values, respectively. The developed method for plasma sample preparation and the evaluated HPLC condition were further applied to an in vivo pharmacokinetic study.
Keywords:Medrogestone
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号