首页 | 本学科首页   官方微博 | 高级检索  
     


Long-term use of high-efficiency vacuum cleaners and residential airborne fungal-spore exposure
Authors:Gregg M. Recer
Affiliation:(1) Department of Earth and Environmental Sciences, University of Texas at Arlington, Room 233A, Geoscience Building, 500 Yates Street, Box 19049, Arlington, TX 76019-0049, USA;(2) Department of Chemistry, State University of New York, College of Environmental Science and Forestry, 1 Forestry Drive, Syracuse, NY 13210, USA;(3) School of Economic, Political and Policy Sciences, University of Texas at Dallas, Box 830688, Richardson, TX 75083, USA
Abstract:Exposure to fungal allergens is an important contributor to allergic respiratory disease, but information on the efficacy of residential fungal allergen-avoidance in allergic-disease management is lacking. Using vacuum cleaners with high-efficiency exhaust filtration is one method recommended for reducing residential allergen exposure levels, but their use to reduce fungal-spore exposure levels has not been evaluated. To evaluate the effectiveness of high-efficiency vacuuming to control airborne fungal-spore levels, fungal bioaerosols were repeatedly assessed over the course of 10 months in homes randomly assigned to groups using either conventionally filtered (control) or high-efficiency-filtered vacuum cleaners for routine vacuum cleaning. Air samples were analyzed for three fungal-spore categories representing taxa with predominantly outdoor sources and one representing taxa that commonly have indoor sources. In a two-way analysis of variance, sampling period had a significant effect on mean levels of all fungal-spore categories. Vacuum cleaner type had a marginally significant effect on the indoor spore category, with one high-efficiency vacuum group mean (of three) significantly lower than one control mean. No effect was observed of vacuum cleaner type on outdoor spore categories. Including home-environment variables in analysis of covariance models strengthened the effect of the vacuum-type treatment on the indoor spore category, with no effect on the three outdoor spore categories. Decreased indoor spore levels vs. controls were only observed in high-efficiency vacuum groups during the last sampling period, at the end of the heating season. The results suggest that using a vacuum with high-efficiency filtered exhaust could have some modest effectiveness in controlling airborne fungal-spore exposure in homes when infiltration of outdoor air is very limited.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号