首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Determination of the diameter of simulated human capillaries using shifted position-diffuse reflectance imaging
Authors:Moritz Späth  Martin Hohmann  Maximilian Rohde  Benjamin Lengenfelder  Florian Stelzle  Florian Klämpfl
Institution:1. Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany;2. Erlangen Graduate School in Advanced Optical Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany

Department of Oral and Maxillofacial Surgery, University Hospital Erlangen, Erlangen, Germany;3. Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany

Erlangen Graduate School in Advanced Optical Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany;4. Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany

Erlangen Graduate School in Advanced Optical Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany

Department of Oral and Maxillofacial Surgery, University Hospital Erlangen, Erlangen, Germany

Abstract:Multiple diseases are associated with a wide spectrum of microvascular dysfunctions, microangiopathies and microcirculation disorders. Monitoring the microcirculation could thus be useful to diagnose many local and systemic circulatory disorders and to supervise critically ill patients. Many of the scores currently available to help identify the condition of a microcirculation disorder are invasive or leave scope for interpretation. Thus, the present study aims to investigate with Monte-Carlo simulations (as numerical solutions of the radiative transfer equation) whether shifted position-diffuse reflectance imaging (SP-DRI), a non-invasive diagnostic technique, reveals information on the capillary diameter to assess the state of the microcirculation. To quantify the SP-DRI signal, the modulation parameter K is introduced. It proves to correlate almost perfectly with the capillary diameter (urn:x-wiley:1864063X:media:jbio202000465:jbio202000465-math-0001), making it a valid parameter for reliably assessing microcirculation. SP-DRI is emerging as an important milestone on the way to early and conveniently diagnosing microcirculation associated diseases.image
Keywords:shifted position-diffuse reflectance imaging  microcirculation  critically ill patients  modulation parameter  turbid media  human capillary  Monte-Carlo simulation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号