首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Label-free reflectometric interference microchip biosensor based on nanoporous alumina for detection of circulating tumour cells
Authors:Kumeria Tushar  Kurkuri Mahaveer D  Diener Kerrilyn R  Parkinson Luke  Losic Dusan
Institution:Ian Wark Research Institute, University of South Australia, Mawson Lakes, SA 5095, Australia.
Abstract:In this report, a label-free reflectometric interference spectroscopy (RIfS) based microchip biosensor for the detection of circulating tumour cells (CTCs) is demonstrated. Highly ordered nanoporous anodic aluminium oxide (AAO) fabricated by electrochemical anodization of aluminium foil was used as the RIfS sensing platform. Biotinylated anti-EpCAM antibody that specifically binds to human cancer cells of epithelial origin such as pancreatic cancer cells (PANC-1) was covalently attached to the AAO surface through multiple surface functionalization steps. Whole blood or phosphate buffer saline spiked with low numbers of pancreatic cancer cells were successfully detected by specially designed microfluidic device incorporating an AAO RIfS sensor, without labour intensive fluorescence labelling and/or pre-enhancement process. Our results show that the developed device is capable of selectively detecting of cancer cells, within a concentrations range of 1000-100,000 cells/mL, with a detection limit of <1000 cells/mL, a response time of <5 min and sample volume of 50 μL of. The presented RIfS method shows considerable promise for translation to a rapid and cost-effective point-of-care diagnostic device for the detection of CTCs in patients with metastatic cancer.
Keywords:
本文献已被 PubMed 等数据库收录!