首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Bovine serum albumin functionalized blue emitting Ti3C2 MXene quantum dots as a sensitive fluorescence probe for Fe3+ ion detection and its toxicity analysis
Authors:Mohammed Ali Al-Duais  Zuhair M Mohammedsaleh  Hamza S Al-Shehri  Yahya S Al-Awthan  Suhair A Bani-Atta  Ali A Keshk  Syed Khalid Mustafa  Adel D Althaqafy  Jozaa N Al-Tweher  Hatem A Al-Aoh  Chellasamy Panneerselvam
Institution:1. Department of Biochemistry, Faculty of Science, University of Tabuk, Tabuk, Saudi Arabia

Biochemistry Unit, Department of Chemistry, Faculty of Science, Ibb University, Ibb, Yemen;2. Department of Medical Laboratory Technology, Faculty of Applied Medical Sciences, University of Tabuk, Tabuk, Saudi Arabia;3. Chemistry Division, King Khalid Military Academy, SANG, Riyadh, Saudi Arabia;4. Department of Biology, Faculty of Science, University of Tabuk, Tabuk, Saudi Arabia

Department of Biology, Faculty of Science, Ibb University, Ibb, Yemen;5. Department of Chemistry, Faculty of Science, University of Tabuk, Tabuk, Saudi Arabia;6. Department of Biology, Faculty of Science, University of Tabuk, Tabuk, Saudi Arabia

Abstract:In the present work, an improved class of protein functionalized fluorescent 2D Ti3C2 MXene quantum dots (MXene QDs) was prepared using a hydrothermal method. Exfoliated 2D Ti3C2 sheets were used as the starting precursor and transport protein bovine serum albumin (BSA) was used to functionalize the MXene QDs. BSA-functionalized MXene QDs exhibited excellent photophysical property and stability at various physiological parameters. High-resolution transmission electron microscopy analysis showed that the BSA@MXene QDs were quasispherical in shape with a size of ~2 nm. The fluorescence intensity of BSA@MXene QDs was selectively quenched in the presence of Fe3+ ions. The mechanism of fluorescence quenching was further substantiated using time-resolved fluorescence and Stern–Volmer analysis. The sensing assay showed a linear response within the concentration range 0–150 μM of Fe3+ ions with excellent limit of detection. BSA@MXene QDs probe showed good selectivity toward ferric ions even in the presence of other potential interferences. The practical applicability of BSA@MXene QDs was further tested in real samples for Fe3+ ion quantification and the sensor had good recovery rates. The cytotoxicity studies of the BSA@MXene QDs toward the human glioblastoma cells revealed that BSA@MXene QDs are biocompatible at lower doses and showed significant cytotoxicity at higher dosages.
Keywords:BSA@MXene QDs  Fe3+ ions  fluorescence detection  human glioblastoma cells  toxicity