Extended Flip-back Schemes for Sensitivity Enhancement in Multidimensional HSQC-type Out-and-back Experiments
Authors:Email author" target="_blank">Tammo?DiercksEmail author  Mark?Daniels  Robert?Kaptein
Institution:(1) Department of NMR Spectroscopy, Bijvoet Center for Biomolecular Research, Utrecht University, 3584, CH, Utrecht, The Netherlands
Abstract:In many NMR experiments, only polarisation of a limited sub-set of all protons is converted into observable coherence. As recently shown by the “longitudinal” TROSY implementation (Pervushin et al. (2002) J. Am. Chem. Soc., 124, 12898–12902) and SOFAST-HMQC (Schanda and Brutscher (2005) J. Am. Chem. Soc., 127, 8014–8015), recovery of unused polarisation can be used indirectly and unspecifically to cool the proton lattice and, thus, accelerate re-equilibration for the selected proton subset. Here we illustrate transfer of this principle to HSQC-based multi-dimensional out-and-back experiments that exploit only polarisation of 15N-bound protons. The presented modifications to the pulse sequences can be implemented broadly and easily, extending standard flip-back of water polarisation to a much larger pool of protons that may comprise all non−15N-bound protons. The underlying orthogonal separation of HN polarisation (selected by the main transfer path) from unused Hu polarisation (flipped-back on the recovery path) is thereby achieved through positive or negative selection by J-coupling, or using band-selective pulses. In practice, Hu polarisation recovery degrades mostly through cumulative pulse imperfections and transverse relaxation; we present, however, strategies to substantially minimise such losses particularly during interim proton decoupling. Depending on the protein’s relaxation properties and the extended flip-back scheme employed, we recovered up to 60% Hu equilibrium polarisation. The concomitant cooling of the proton lattice afforded substantial gains of more than 40%, relative to the water-only flip-back version, in the fast pulsing regime with re-equilibration delays τ much shorter than optimal (τopt = 1.25 · T1(HN)). These would be typically employed if resolution requirements dominate the total measurement time. Contrarily, if sensitivity is limiting and optimal interscan delays τopt can be set (optimal pulsing regime), the best of the presented flip-back schemes may still afford up to ca. 10% absolute sensitivity enhancement.
Keywords:extended flip-back  fast pulsing regime  magnetisation recovery  orthogonal polarisation separation  resolution enhancement  sensitivity enhancement
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号