Use of liquid chromatography to measure chlorite production by Nitrobacter winogradskyi NRCC26538
Authors:Russell K Hynes
Institution:Plant Biotechnology Institute, National Research Council of Canada, Saskatoon, Saskatchewan, Canada
Abstract:A high-pressure liquid chromatography (HPLC) technique, previously developed for nitrite (NO2) and nitrate (NO3) measurements 3], was used to measure chlorite (ClO2) production by Nitrobacter winogradskyi. The determination of ClO2 by HPLC involves monitoring the column effluent with a UV detector at 214 or 254 nm. Although the absorbance of ClO2 at 214 nm was about 5 times greater than at 254 nm, interference from other compounds in the culture filtrates of N. winogradskyi contributed to an unstable detector signal. The detection limit at 254 nm for ClO2 in deionized water was about 1 μM.The measurement of ClO2 in N. winogradskyi culture filtrates was done with detection at 254 nm. The maximum concentration of ClO2 produced by anaerobically incubated cell suspensions of N. winogradskyi was about 80 μM.
Keywords:Nitrobacter winogradskyi            Chlorite  Nitrification  (HPLC)
本文献已被 ScienceDirect 等数据库收录!