首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Comprehensive simulation on morphological and mechanical properties of trigger finger – A cadaveric model
Institution:1. Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208, USA;2. Department of Physical Medicine & Rehabilitation, Northwestern University Feinberg School of Medicine, 303 Chicago Ave., Chicago, IL 60611, USA;3. Department of Physical Therapy & Human Movement Sciences, Northwestern University Feinberg School of Medicine, 303 Chicago Ave., Chicago, IL 60611, USA;4. Sensory Motor Performance Program, Rehabilitation Institute of Chicago, 345 E Superior Street, Chicago, IL 60611, USA;5. Edward Hines, Jr. VA Hospital, 5000 S, Fifth Avenue, P.O. Box 5000 (151), Hines, IL 60141, USA;6. Department of Orthopaedic Surgery and Rehabilitation, Stritch School of Medicine, Loyola University – Chicago, Maguire Building – 1700, 2160 South 1st Ave, Maywood, IL 60153, USA
Abstract:Trigger finger has long been a common disorder in hand orthopedics. To clarify the unknown causative factors regarding the disease, numerous experiments were done on human cadavers, including tendon forces, tendon moment arm, mechanical properties of the pulley, gliding resistance, etc. However, most of these studies were conducted on normal fingers. As the etiology of trigger finger is still controversial on whether it is an outcome of tendon nodule or pulley scarring, in this study, a trigger finger model was built combining both the nodule created by silicone gel injection and pulley constriction by external compression. Indentation and gliding resistance tests were performed on cadaveric specimens to verify the model. Results showed that after silicone gel injection into the tendon, a significant increase in thickness was found. In addition, no significant difference was found in the toe region compressive modulus of the tendon after injection. Moreover, maximum, drop of gliding resistance and work of extension were all found to be significantly larger as the severity of triggering increased. Our results indicated we have developed a feasible cadaver model simulating trigger finger nodule which could be utilized for further experiments to elucidate other causative factors and biomechanical features of trigger finger in the future.
Keywords:Trigger finger  Mechanical property  Gliding resistance  Human cadaveric model
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号