首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Simultaneous carbon and nitrogen removal from piggery wastewater using loop configuration microbial fuel cell
Authors:JH Ryu  HL Lee  YP Lee  TS Kim  MK Kim  DTN Anh  HT Tran  DH Ahn
Institution:1. Department of Environmental Engineering and Biotechnology, Myongji University, San 38-2 Namdong, Yongin, Kyonggido 449-728, Republic of Korea;2. Center for Advanced Materials Technology, National Center for Technological Progress (NACENTECH), C6 Thanh Xuan Bac, Thanh Xuan District, Hanoi, Viet Nam
Abstract:Simultaneous carbon and nitrogen removal using loop configuration microbial fuel cell (MFC) with relatively large size of 5 L was investigated in this study. Four MFC reactors were constructed with a loop configuration to eliminate the pH gradient, and the reactor performance was examined with different separators and cathode materials. The performance of the reactors in terms of electricity generation and contaminant removal rate was examined. Results showed that a maximum power density of 1415.6 mW/m3 (The empty bed volume of anode chamber) was obtained at a current density of 3258.5 mA/m3 with cation exchange membrane as separator and graphite felt (Pt coated) as cathode using the piggery wastewater as feed, and the organic removal rate obtained was approximately 0.523 kg COD/m3/d (total anode chamber) with nitrogen removal rate of 0.194 kg N/m3/d (total cathode chamber).
Keywords:Microbial fuel cell  Loop configuration  Pt coated graphite felt  Pt coated titanium  Scale-up
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏