Devices for Diagnostics and Lithium Collection on the T-11M and T-10 Tokamaks. First Results |
| |
Authors: | M Yu Zharkov A V Vertkov I E Lyublinski V A Vershkov A V Karpov S V Mirnov |
| |
Institution: | 1.“Red Star” Joint-Stock Company,Moscow,Russia;2.National Research Nuclear University “MEPhI,”,Moscow,Russia;3.National Research Center “Kurchatov Institute,”,Moscow,Russia;4.Troitsk Institute for Innovation and Thermonuclear Research,Troitsk, Moscow,Russia |
| |
Abstract: | The use of lithium as a material of the tokamak in-vessel plasma-facing components made it necessary to develop appropriate diagnostic instruments. For the T-10 and T-11M tokamaks, devices have been developed that allow one to investigate the processes of lithium transport in the tokamak scrape-off layer, the dynamics of lithium deposition at different temperatures of the collecting surface in real time by using a piezoelectric quartz detector, adsorption and desorption of the plasma-forming gas by lithium, and the influence of the electric field on the process of lithium collection. The plasma parameters are monitored using Langmuir probes. The developed devices can be used to extract lithium deposited on the tokamak vessel wall without breaking vacuum conditions. For these purposes, a gateway and a vacuum input without bellows have been designed on the basis of an innovative liquid-metal coupling. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|