首页 | 本学科首页   官方微博 | 高级检索  
     


Assessment of the biological variation of plasma tissue inhibitor of metalloproteinases-1
Authors:Frederiksen C B  Lomholt A F  Lottenburger T  Davis G J  Dowell B L  Blankenstein M A  Christensen I J  Brunner N  Nielsen H J
Affiliation:Department of Surgical Gastroenterology, Hvidovre University Hospital, Hvidovre - Denmark. frederiksen@dadlnet.dk
Abstract:BACKGROUND: Tissue inhibitor of metalloproteinases-1 (TIMP-1) measurements in plasma may be useful for the early detection and prognosis of colorectal cancer (CRC). Data on analytical performance and normal intra- and interindividual biological variation are required in order to interpret the utility of TIMP-1 in CRC. The aim of this study was to establish the biological and analytical variation of plasma TIMP-1 in volunteers. MATERIAL AND METHODS: Three separate studies were undertaken. 1: Plasma was collected from 23 volunteers 6 times within a 3-week period, first in September 2004 (round R] 1), then repeated in May 2005 (R2) and May 2006 (R3) in the same group of individuals. TIMP-1 levels were determined by the MAC15 ELISA assay and with the Abbott ARCHITECT i2000 Immunoanalyzer. 2: Circadian variation was evaluated in plasma collected 7 times within a 24-hour period (n=16). 3: Effects of physical exercise were evaluated in plasma collected before and after bicycling (n=14). In studies 2 and 3 TIMP-1 levels were determined with the MAC15 ELISA assay only. RESULTS: A significant correlation between TIMP-1 MAC15 and ARCHITECT i2000 was shown (rs=0.78, p<0.002), with consistently higher levels being detected by the ARCHITECT i2000. Median levels of TIMP-1 (ARCHITECT) at 8 a.m. in each round were 74.9 ng/mL (range 65.7-89.9) (R1), 87.3 ng/mL (range 72.7-127.9) (R2), and 81.9 ng/mL (range 66.8-113.6) (R3). The within-subject variation was 10.7%, the variation between rounds was 7.4%, and the intraclass correlation was 46.2%. Comparison between the 3 rounds and time of collection showed that TIMP-1 values decreased by 11% after storage for more than 16 months (p=0.0002). A systematic circadian variation in plasma TIMP-1 levels was not observed (p=0.17). No significant variation of plasma TIMP-1 was found in relation to physical exercise (p=0.92 global test]). CONCLUSION: Levels of plasma TIMP-1 in volunteers show limited circadian, day-to-day, week-to-week and season-to-season variation. In addition, physical exercise has no impact on plasma TIMP-1 levels. Possible storage-dependent decreases in plasma TIMP-1 levels warrant further investigation.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号