首页 | 本学科首页   官方微博 | 高级检索  
   检索      

三维标测环肺静脉前庭隔离术后肺静脉狭窄的相关因素
引用本文:夏洪远,董玉梅,张彤,张兰,张丽丽,卫丽,曹雪,李学奇.三维标测环肺静脉前庭隔离术后肺静脉狭窄的相关因素[J].生物磁学,2014(3):457-460.
作者姓名:夏洪远  董玉梅  张彤  张兰  张丽丽  卫丽  曹雪  李学奇
作者单位:哈尔滨医科大学附属第四医院心内科,黑龙江哈尔滨150001
基金项目:黑龙江省青年科学技术专项资金(QC2012C129);哈尔滨市科技局科技创新人才研究专项资金项目(青年科技创新人才(2009RFQXS021)
摘    要:目的:探讨房颤射频消融术后肺静脉狭窄的相关因素,为其预防提供依据。方法:收集113例射频消融房颤患者的临床资料,记录射频术中消融时间、阻抗和温度;术后6个月64层CT左房-肺静脉重建随访,统计肺静脉狭窄的发生率;多元Logistic回归分析肺静脉狭窄的相关因素。结果:依据肺静脉数量计算的肺静脉狭窄率为3.4%,按照患者数量计算的肺静脉狭窄率为7.7%。多元Logistic回归分析,初始50例手术较其后病例的OR为2.167,95%CI=I.038-9.857,P=0.046,消融时间在总消融时间均数之上的患者比在均数之下者OR为2.856,95%CI=1.352-6.043,P=0.021。结论:初始50例手术和消融时间长是房颤射频消融术后肺静脉狭窄的相关因素。

关 键 词:房颤  射频消融  肺静脉狭窄  相关因素

The Correlation Factors of Pulmonary Vein Stenosis Complicating Pulmonary Vein Antrum Isolation Guiding by 3D Mapping System for Atrial Fibrillation
XIA Hong-yuan,DONG Yu-mei,ZHANG Tong,ZHANG Lan,ZHANG Li-li,WEI Li,CAO Xue,LI Xue-qi.The Correlation Factors of Pulmonary Vein Stenosis Complicating Pulmonary Vein Antrum Isolation Guiding by 3D Mapping System for Atrial Fibrillation[J].Biomagnetism,2014(3):457-460.
Authors:XIA Hong-yuan  DONG Yu-mei  ZHANG Tong  ZHANG Lan  ZHANG Li-li  WEI Li  CAO Xue  LI Xue-qi
Institution:(Dept of Cardiology, The Fourth ADTliated Hospital oHarbin Medical Universi(y, Harbin, Heffongfiang, 150001, China)
Abstract:Objective: To explore what are the correlation factors of pulmonary vein stenosis following radiofrequency ablation guiding by 3D mapping system for atrial fibrillation in order to offer evidence for pulmonary vein stenosis prevention. Methods: The clinical data of 113 consecutive patients with atrial fibrillation underwent pulmonary vein antrum isolation guiding by 3D mapping(Carto) systerm were collected and the radiofrequency time, impedance and temperature during the index procedure were also recorded for analyzing. The prevalence of pulmonary vein stenosis was calculated according to the pulmonary vein diameter detected by 64-slice CT reconstruction in 6 months follow-up. The possible correlation factors were evaluated using multivariate Logistic regression analysis. Results: The pulmonary vein stenosis occurred in 6 out of 104 patients(7.7%), whereas, the frequency of pulmonary vein stenosis was of 3.4% according to the amount of pulmonary vein. Multivariate Logistic regression analysis indicated pulmonary vein stenosis was more likely occurred in initial 50 cases (OR=2.167, 95% CI=1.038-9.857 ,P=0.046) and in patients with longer radiofrequency time(OR=2.856, 95% CI=1.352~6.043 ,P=0.021). Conclusion: Initial 50 cases and longer radiofrequency time are the correlation factors of of pulmonary vein stenosis complicating radioffequency ablation guiding by 3D mapping system for atrial fibrillation.
Keywords:Atrial fibrillation  Radiofrequency ablation  Pulmonary vein stenosis  Correlation factor
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏