首页 | 本学科首页   官方微博 | 高级检索  
     


The prediction of intake potential and organic matter digestibility of grass silages by near infrared spectroscopy analysis of undried samples
Authors:F.J Gordon  K.M Cooper  R.S Park  R.W.J Steen
Affiliation:

a Agricultural Research Institute of Northern Ireland, Hillsborough Co. Down BT26 6DR Northern Ireland

b Department of Agricultural and Environmental Science, Department of Agriculture for Northern Ireland, Newforge Lane Belfast BT9 5PX Northern Ireland

Abstract:A study was undertaken to examine a range of sample preparation and near infrared reflectance spectroscopy (NIRS) methodologies, using undried samples, for predicting organic matter digestibility (OMD g kg−1) and ad libitum intake (g kg−1 W0.75) of grass silages. A total of eight sample preparation/NIRS scanning methods were examined involving three extents of silage comminution, two liquid extracts and scanning via either external probe (1100-2200 nm) or internal cell (1100-2500 nm). The spectral data (log 1/R) for each of eight methods were examined by three regression techniques each with a range of data transformations. The 136 silages used in the study were obtained from farms across Northern Ireland, over a two year period, and had in vivo OMD (sheep) and ad libitum intake (cattle) determined under uniform conditions. In the comparisons of the eight sample preparation/scanning methods, and the differing mathematical treatments of the spectral data, the sample population was divided into calibration (n = 91) and validation (n = 45) sets. The standard error of performance (SEP) on the validation set was used in comparisons of prediction accuracy. Across all 8 sample preparation/scanning methods, the modified partial least squares (MPLS) technique, generally minimized SEP's for both OMD and intake. The accuracy of prediction also increased with degree of comminution of the forage and with scanning by internal cell rather than external probe. The system providing the lowest SEP used the MPLS regression technique on spectra from the finely milled material scanned through the internal cell. This resulted in SEP and R2 (variance accounted for in validation set) values of 24 (g/kg OM) and 0.88 (OMD) and 5.37 (g/kg W0.75) and 0.77 (intake) respectively. These data indicate that with appropriate techniques NIRS scanning of undried samples of grass silage can produce predictions of intake and digestibility with accuracies similar to those achieved previously using NIRS with dried samples.
Keywords:Grass silage   Intake prediction   Digestibility prediction   Near infrared spectroscopy   NIRS
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号