A bio-inspired two-layer multiple-walled carbon nanotube-polymer composite sensor array and a bio-inspired fast-adaptive readout circuit for a portable electronic nose
Authors:Wang L C  Tang K T  Chiu S W  Yang S R  Kuo C T
Affiliation:Department of Materials Science and Engineering, National Chiao Tung University, Taiwan.
Abstract:We report a fully integrated, portable, battery-operated electronic nose system comprising a bio-inspired two-layer multiple-walled carbon nanotube (MWNT)-polymer composite sensor array, a bio-inspired fast-adaptive readout circuit, and a microprocessor embedded with a pattern recognition algorithm. The two-layer MWNT-polymer composite sensor is simple to operate, and the membrane quality can be easily controlled. These two-layer membranes have improved sensitivity and stability. The fast-adaptive readout circuit responds to the sensor response, while tuning out the long-term constant background humidity, temperature, and odors. This portable electronic nose system successfully classified four complex alcohol samples 40 times for each sample; these samples were sake, sorghum liquor, medical liquor, and whisky.