首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Femoral stiffness and strength critically depend on loading angle: a parametric study in a mouse-inbred strain
Authors:Romain Voide  G Harry van Lenthe  Ralph Müller
Institution:Institute for Biomedical Engineering, University and ETH Zürich, Zürich, Switzerland.
Abstract:Biomechanical tests of human femora have shown that small variations of the loading direction result in significant changes in measured bone mechanical properties. However, the heterogeneity in geometrical and bone tissue properties does not make human bones well suited to reproducibly assess the effects of loading direction on stiffness and strength. To precisely quantify the influence of loading direction on stiffness and strength of femora loaded at the femoral head, we tested femora from C57BL/6 inbred mice. We developed an image-based alignment protocol and investigated the loading direction influence on proximal femur stiffness and strength. An aluminum femoral phantom and C57BL/6 femora were tested under compression with different loading directions. Both tests, with the aluminum phantom and the murine bones, showed and quantified the linear dependence of stiffness on loading direction: a 5 degrees change in loading direction resulted in almost 30% change in stiffness. Murine bone testing also revealed and quantified the variation in strength due to loading direction: 5 degrees change in loading direction resulted in 8.5% change in strength. In conclusion, this study quantified, for the first time, the influence of misalignment on bone stiffness and strength for femoral head loading. We showed the extreme sensitivity of this site regarding loading direction.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号