首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Effects of static magnetic fields on nicotinic cholinergic receptor function
Authors:Tolosa María Fernanda  Bouzat Cecilia  Cravero Walter Rubén
Institution:Departamento de Física, Universidad Nacional del Sur, Bahía Blanca, Argentina.
Abstract:Ligand-gated ion channel kinetics were studied in mammalian transfected cells encoding adult mouse muscle acetylcholine (ACh) receptors. We measured macroscopic and single-channel currents using the outside-out and cell-attached patch-clamp configurations. Cultured cells were exposed to moderate intensity inhomogeneous static magnetic fields up to 180 mT and measurements were performed for temperatures ranging from 5 to 50 °C. We found no significant changes in ACh-elicited macroscopic or single-channel currents. We observed the expected dependence in current decay constants with temperature, but negligible magnetic field influence on the channel's kinetics.
Keywords:AChR  patch‐clamp  static magnetic field
本文献已被 PubMed 等数据库收录!