首页 | 本学科首页   官方微博 | 高级检索  
     


Odour and ammonia emissions from intensive pig units in Ireland
Authors:Hayes E T  Curran T P  Dodd V A
Affiliation:Department of Biosystems Engineering, University College Dublin, Earlsfort Terrace, Dublin 2, Ireland.
Abstract:Odour and ammonia emissions were measured at four intensive pig units in Ireland. Odour samples were collected on-site and analysed for odour concentration using an olfactometer. Ammonia concentrations in the exhaust ventilation air were measured using a portable sensor. The geomean odour emission rates over the four pig units were 17.2, 44.4, 4.3, 9.9 and 16.8 ou(E) s(-1) animal(-1) for dry sows, farrowing sows, first stage weaners, second stage weaners and finishers, respectively. The mean ammonia emission rates, measured at two of the units, were 12.1, 17.1, 1.4, 2.9 and 10.0 g d(-1) animal(-1) for dry sows, farrowing sows, first stage weaners, second stage weaners and finishers, respectively. In general, the odour and ammonia emission rates were comparable to those reported in literature, although some odour emission rate figures were noticeably lower for finishing pigs in this study. The variability in the data highlights the need for individual site assessment.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号