首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Periosteal versus true cross‐sectional geometry: A comparison along humeral,femoral, and tibial diaphyses
Authors:Alison A Macintosh  Thomas G Davies  Timothy M Ryan  Colin N Shaw  Jay T Stock
Institution:1. PAVE Research Group, Department of Archaeology & Anthropology, University of Cambridge, Cambridge, CB2 3DZ, UK;2. Department of Anthropology, Pennsylvania State University, University Park, PA 16802;3. Center for Quantitative X‐Ray Imaging, EMS Energy Institute, Pennsylvania State University, University Park, PA 16802;4. McDonald Institute for Archaeological Research, Department of Archaeology and Anthropology, University of Cambridge, Cambridge, CB2 3DZ, UK
Abstract:Cross‐sectional geometric (CSG) properties of human long bone diaphyses are typically calculated from both periosteal and endosteal contours. Though quantification of both is desirable, periosteal contours alone have provided accurate predictions of CSG properties at the midshaft in previous studies. The relationship between CSG properties calculated from external contours and “true” (endosteal and periosteal) CSG properties, however, has yet to be examined along the whole diaphysis. Cross‐sectional computed tomography scans were taken from 21 locations along humeral, femoral, and tibial diaphyses in 20 adults from a late prehistoric central Illinois Valley cemetery. Mechanical properties calculated from images with (a) artificially filled medullary cavities (“solid”) and (b) true unaltered cross‐sections were compared at each section location using least squares regression. Results indicate that, in this sample, polar second moments of area (J), polar section moduli (Zp), and cross‐sectional shape (Imax/Imin) calculated from periosteal contours correspond strongly with those calculated from cross‐sections that include the medullary cavity. Correlations are high throughout most of the humeral diaphysis and throughout large portions of femoral and tibial diaphyses (R2 = 0.855–0.998, all P < 0.001, %SEE ≤ 8.0, %PE ≤ 5.0), the major exception being the proximal quarter of the tibial diaphysis for J and Zp. The main source of error was identified as variation in %CA. Results reveal that CSG properties quantified from periosteal contours provide comparable results to (and are likely to detect the same differences among individuals as) true CSG properties along large portions of long bone diaphyses. Am J Phys Anthropol, 2013. © 2013 Wiley Periodicals, Inc.
Keywords:cross‐sectional geometry  biomechanics  humerus  femur  tibia
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号