首页 | 本学科首页   官方微博 | 高级检索  
   检索      


A High Throughput In Vivo Assay for Taste Quality and Palatability
Authors:R Kyle Palmer  Daniel Long  Francis Brennan  Tulu Buber  Robert Bryant  F Raymond Salemme
Institution:1. Opertech Bio, Inc., Philadelphia, Pennsylvania, United States of America.; 2. Genomind, LLC, Chalfont, Pennsylvania, United States of America.; 3. Asheville Flavor Innovations, LLC, Asheville, North Carolina, United State of America.; 4. Imiplex, LLC, Bristol, Pennsylvania, United State of America.; Barnard College, Columbia University, United States of America,
Abstract:Taste quality and palatability are two of the most important properties measured in the evaluation of taste stimuli. Human panels can report both aspects, but are of limited experimental flexibility and throughput capacity. Relatively efficient animal models for taste evaluation have been developed, but each of them is designed to measure either taste quality or palatability as independent experimental endpoints. We present here a new apparatus and method for high throughput quantification of both taste quality and palatability using rats in an operant taste discrimination paradigm. Cohorts of four rats were trained in a modified operant chamber to sample taste stimuli by licking solutions from a 96-well plate that moved in a randomized pattern beneath the chamber floor. As a rat’s tongue entered the well it disrupted a laser beam projecting across the top of the 96-well plate, consequently producing two retractable levers that operated a pellet dispenser. The taste of sucrose was associated with food reinforcement by presses on a sucrose-designated lever, whereas the taste of water and other basic tastes were associated with the alternative lever. Each disruption of the laser was counted as a lick. Using this procedure, rats were trained to discriminate 100 mM sucrose from water, quinine, citric acid, and NaCl with 90-100% accuracy. Palatability was determined by the number of licks per trial and, due to intermediate rates of licking for water, was quantifiable along the entire spectrum of appetitiveness to aversiveness. All 96 samples were evaluated within 90 minute test sessions with no evidence of desensitization or fatigue. The technology is capable of generating multiple concentration–response functions within a single session, is suitable for in vivo primary screening of tastant libraries, and potentially can be used to evaluate stimuli for any taste system.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号