首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Effect of hydrogen peroxide on human tendon allograft
Authors:E M H Gardner  N VonderHeide  R Fisher  G Brooker  P J Yates
Institution:1. Perth Bone and Tissue Bank, Nedlands, WA, Australia
Abstract:Bacterial contamination of tendon allografts at the completion of processing has historically been about 2 %, with tendons that are found to be culture positive being discarded. Treatment of tendon allograft with hydrogen peroxide at the beginning of tissue processing may reduce bacterial contamination, however, the potential side effects of hydrogen peroxide treatment include hydrolysis of the collagen and this may alter the mechanical properties of the graft. Pairs of human tendons were used. One was washed in 3 % hydrogen peroxide for 5 min and the untreated tendon was used as a control. The ultimate tensile strength of the tendons was determined using a material testing machine. A freeze clamp technique was used to hold the tendons securely at the high loads required to cause tendon failure. There was no statistical difference in the ultimate tensile strength between the treated and untreated tendons. Mean strength ranged from Extensor Hallucis Longus at 588 Newtons to Tibialis Posterior at 2,366 Newtons. Hydrogen peroxide washing may reduce bacterial contamination of tendon allograft and does not affect the strength of the tendon.
Keywords:
本文献已被 SpringerLink 等数据库收录!