首页 | 本学科首页   官方微博 | 高级检索  
     


The inter- and intra-unit variability of a low-cost GPS data logger/receiver to study human outdoor walking in view of health and clinical studies
Authors:Abraham Pierre  Noury-Desvaux Bénédicte  Gernigon Marie  Mahé Guillaume  Sauvaget Thomas  Leftheriotis Georges  Le Faucheur Alexis
Affiliation:Laboratory of Vascular Investigations and Sports Medicine, University Hospital, Angers, France.
Abstract:

Purpose

The present study evaluates the intra- and inter-unit variability of the GlobalSat® DG100 GPS data logger/receiver (DG100) when estimating outdoor walking distances and speeds.

Methods

Two experiments were performed using healthy subjects walking on a 400 m outdoor synthetic track. The two experiments consisted of two different outdoor prescribed walking protocols with distances ranging from 50 to 400 m. Experiment 1 examined the intra-unit variability of the DG100 (test-retest reproducibility) when estimating walking distances. Experiment 2 examined the inter-unit variability of four DG100 devices (unit to unit variability) when estimating walking distances and speeds.

Results

The coefficient of variation [95% confidence interval], for the reliability of estimating walking distances, was 2.8 [2.5–3.2] %. The inter-unit variability among the four DG100 units tested ranged from 2.8 [2.5–3.2] % to 3.9 [3.5–4.4] % when estimating distances and from 2.7 [2.4–3.0] % to 3.8 [3.4–4.2] % when estimating speeds.

Conclusion

The present study indicates that the DG100, an economical and convenient GPS data logger/receiver, can be reliably used to study human outdoor walking activities in unobstructed conditions. This device let facilitate the use of GPS in studies of health and disease.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏