首页 | 本学科首页   官方微博 | 高级检索  
     


The impact of utilizing different optical coherence tomography devices for clinical purposes and in multiple sclerosis trials
Authors:Warner Christina V  Syc Stephanie B  Stankiewicz Aleksandra M  Hiremath Girish  Farrell Sheena K  Crainiceanu Ciprian M  Conger Amy  Frohman Teresa C  Bisker Esther R  Balcer Laura J  Frohman Elliot M  Calabresi Peter A  Saidha Shiv
Affiliation:Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, Maryland, United States of America.
Abstract:Optical coherence tomography (OCT) derived retinal measures, particularly peri-papillary retinal nerve fiber layer (RNFL) thickness, have been proposed as outcome measures in remyelinating and neuroprotective trials in multiple sclerosis (MS). With increasing utilization of multiple centers to improve power, elucidation of the impact of different OCT technologies is crucial to the design and interpretation of such studies. In this study, we assessed relation and agreement between RNFL thickness and total macular volume (in MS and healthy controls) derived from three commonly used OCT devices: Stratus time-domain OCT, and Cirrus HD-OCT and Spectralis, two spectral-domain (SD) OCT devices. OCT was performed on both Cirrus HD-OCT and Stratus in 229 participants and on both Cirrus HD-OCT and Spectralis in a separate cohort of 102 participants. Pearson correlation and Bland-Altman analyses were used to assess correlation and agreement between devices. All OCT retinal measures correlated highly between devices. The mean RNFL thickness was 7.4 μm lower on Cirrus HD-OCT than Stratus, indicating overall poor agreement for this measurement between these machines. Further, the limits of agreement (LOA) between Cirrus HD-OCT and Stratus were wide (-4.1 to 18.9 μm), indicating poor agreement at an individual subject level. The mean RNFL thickness was 1.94 μm (LOA: -5.74 to 9.62 μm) higher on Spectralis compared to Cirrus HD-OCT, indicating excellent agreement for this measurement across this cohort. Although these data indicate that these three devices agree poorly at an individual subject level (evidenced by wide LOA in both study cohorts) precluding their co-utilization in everyday practice, the small difference for mean measurements between Cirrus HD-OCT and Spectralis indicate pooled results from these two SD-devices could be used as outcome measures in clinical trials, provided patients are scanned on the same machine throughout the trial, similar to the utilization of multiple different MRI platforms in MS clinical trials.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号