首页 | 本学科首页   官方微博 | 高级检索  
     


Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT
Authors:Britt-Marie Kjellman  Mats Fredrikson  Gunilla Glad-Mattsson  Folke Sjöberg  Fredrik RM Huss
Affiliation:1. The Burn unit, Dept. of Plastic Surgery, Hand Surgery and Burns, University Hospital of Link?ping, Link?ping, Sweden
2. Department of Clinical and Experimental Medicine, Faculty of Health Sciences, Link?ping University, Link?ping, Sweden
3. Department of Surgical Sciences, Plastic Surgery, Uppsala University, Uppsala, Sweden
Abstract:

Background

Hypothermia in burns is common and increases morbidity and mortality. Several methods are available to reach and maintain normal core body temperature, but have not yet been evaluated in critical care for burned patients. Our unit's ordinary technique for controlling body temperature (Bair Hugger®+ radiator ceiling + bed warmer + Hotline®) has many drawbacks e.g.; slow and the working environment is hampered. The aim of this study was to compare our ordinary heating technique with newly-developed methods: the Allon?2001 Thermowrap (a temperature regulating water-mattress), and Warmcloud (a temperature regulating air-mattress).

Methods

Ten consecutive burned patients (> 20% total burned surface area and a core temperature < 36.0°C) were included in this prospective, randomised, comparative study. Patients were randomly exposed to 3 heating methods. Each treatment/measuring-cycle lasted for 6 hours. Each heating method was assessed for 2 hours according to a randomised timetable. Core temperature was measured using an indwelling (bladder) thermistor. Paired t-tests were used to assess the significance of differences between the treatments within the patients. ANOVA was used to assess the differences in temperature from the first to the last measurement among all treatments. Three-way ANOVA with the Tukey HSD post hoc test and a repeated measures ANOVA was used in the same manner, but included information about patients and treatment/measuring-cycles to control for potential confounding. Data are presented as mean (SD) and (range). Probabilities of less than 0.05 were accepted as significant.

Results

The mean increase, 1.4 (SD 0.6°C; range 0.6-2.6°C) in core temperature/treatment/measuring-cycle highly significantly favoured the Allon?2001 Thermowrap in contrast to the conventional method 0.2 (0.6)°C (range -1.2 to 1.5°C) and the Warmcloud 0.3 (0.4)°C (range -0.4 to 0.9°C). The procedures for using the Allon?2001 Thermowrap were experienced to be more comfortable and straightforward than the conventional method or the Warmcloud.

Conclusions

The Allon?2001 Thermowrap was more effective than the Warmcloud or the conventional method in controlling patients' temperatures.
Keywords:
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号