首页 | 本学科首页   官方微博 | 高级检索  
   检索      


An innovative application of a small-scale motion analysis technique to quantify human skin deformation in vivo
Authors:Jamaluddin Mahmud  Cathy A Holt  Sam L Evans
Institution:1. Neuroscience Research, Australia;2. Prince of Wales Clinical School, the University of New South Wales, Australia;3. School of Medical Science, the University of New South Wales, Australia;4. Murray Maxwell Biomechanics Lab, Kolling Insitute of Medical Research, Sydney Medical School, the University of Sydney, Australia;1. Department of Mechanical Engineering, Sir Frederick Mappin Building, University of Sheffield, UK;2. Department of Electronic and Electrical, University of Sheffield, UK;3. General Engineering and Research Institute, Liverpool John Moors University, Byrom Street, Liverpool L3 3AF, UK
Abstract:This study highlights a new experimental method developed to measure full-field deformation of human skin in vivo. The technique uses a small-scale Qualisys (Sweden) 3D motion capture system and an array of reflective markers placed on the forearm of five healthy volunteers. A load of up to 1.5 N was applied to induce skin deformation by pulling a fine wire attached to the centre of the marker configuration. Loading and marker displacements were recorded simultaneously. 3D marker trajectory data was generated for three different load directions. Tests were repeated to investigate accuracy and repeatability. Calibration results indicate the accuracy of the motion capture system with an average residual of 0.05 mm. The procedure was found to be repeatable and accurate for five repeated tests of measured displacements with a maximum variance of 5%. Experimental data are presented to demonstrate robustness and the ability to produce significant outputs. For all five subjects, at 1 N load, the mean and standard deviations of skin axial and lateral displacements were found to be 11.7±1.6 mm and 12.3±3.3 mm, respectively. The axial displacements ratio (u90/u0) ranges from 0.63 to 1.45 with mean±standard deviation of 0.982±0.34 and 0.982±0.32 for left and right arms, respectively. The experiments generated useful and accurate data that can be used to study the viscoelastic, hyperelastic or anisotropic behaviour of human skin. The measured displacements will be analysed further to determine the mechanical properties of skin using inverse Finite Element Analysis and Ogden model.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号