首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Wall shear over high degree stenoses pertinent to atherothrombosis
Authors:David L Bark  David N Ku
Institution:1. School of Mechanical Engineering, University of Adelaide, South Australia 5005, Australia;2. Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, SA 5000, Australia;1. Faculty of Mechanical Engineering, Sharif University of Technology, Tehran, Iran;2. Faculty of Mechanical Engineering, Babol Noshirvani University of Technology, Babol, Iran;3. ANZAC Research Institute, the University of Sydney, Sydney NSW 2139, Australia;4. Department of Mechanical Engineering, Khomeinishahr Branch, Islamic Azad University, Khomeinishahr, Iran;5. Faculty of Medicine and Health Sciences, Macquarie University, Sydney NSW 2109, Australia;6. Laboratory of Magnetism and Magnetic Materials, Advanced Institute of Materials Science, Ton Duc Thang University, Ho Chi Minh City, Vietnam;7. Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City, Vietnam
Abstract:Atherothrombosis can induce acute myocardial infarction and stroke by progressive stenosis of a blood vessel lumen to full occlusion. Since thrombus formation and embolization may be shear-dependent, we quantify the magnitude of shear rates in idealized severely stenotic coronary arteries (≥75% by diameter) using computational fluid dynamics to characterize the shear environment that may exist during atherothrombosis. Maximum shear rates in severe short stenoses were found to exceed 250,000 s?1 (9500 dynes/cm2) and can reach a peak value of 425,000 s?1 for a 98% stenosis. These high shear rates exceed typical shear used for in vitro blood flow experiments by an order of magnitude, indicating the need to examine thrombosis at very high shear rates. Pulsatility and stenosis eccentricity were found to have minor effects on the maximum wall shear rates in severe stenoses. In contrast, increases in the stenosis length reduced the maximum shear to 107,000 s?1 (98% stenosis), while surface roughness could increase focal wall shear rates to a value reaching 610,000 s?1 (90% stenosis). The “shear histories” of circulating platelets in these stenoses are far below reported activation thresholds. Platelets may be required to form bonds in 5 μs and resist shear forces reaching 8000 pN per platelet. Arterial thrombosis occurs in the face of pathological high shear stress, creating rapid and strong bonds without prior activation of circulating platelets.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号