首页 | 本学科首页   官方微博 | 高级检索  
     


A novel green spectrofluorimetric method for simultaneous determination of antazoline and tetryzoline in their ophthalmic formulation
Authors:Ola G. Hussein  Dina A. Ahmed  Mohamed Abdelkawy  Mamdouh R. Rezk  Yasmin Rostom
Affiliation:1. Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Future University in Egypt, Cairo, 11835 Egypt;2. Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Future University in Egypt, Cairo, 11835 Egypt

Contribution: Conceptualization, Data curation, Formal analysis, ​Investigation, Methodology, Resources, Supervision, Writing - review & editing;3. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Cairo University, Cairo, Egypt

Contribution: Methodology, Project administration, Supervision, Validation, Visualization, Writing - review & editing;4. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Cairo University, Cairo, Egypt

Contribution: Data curation, Formal analysis, Methodology, Project administration, Supervision, Validation, Visualization, Writing - review & editing;5. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Cairo University, Cairo, Egypt

Abstract:A novel spectrofluorimetric method has been developed for determination of antazoline (ANT) and tetryzoline (TET) in their pharmaceutical formulation. A combined application of synchronous spectrofluorimetry and second derivative mathematical treatment was developed. The proposed method depends on reacting the cited drugs with dansyl chloride (DNS-Cl) being a suitable derivatizing agent generating highly fluorescent derivatives measured at emission wavelengths of 703.0 and 642.0 nm after excitation wavelengths of 350.0 and 320.0 nm for ANT and TET, respectively. The joint use of synchronous spectrofluorimetry with second derivative mathematical treatment is for the first time to be developed and optimized in aid of using fluorescence data manager software generating second derivative peak amplitudes at 556.5 nm for ANT and 516.7 nm for TET. Linear responses have been represented over a wide range of concentration (0.5–12.0 μg/mL for ANT and 0.5–10.0 μg/mL for TET). Additionally, statistical comparison of the developed method with the official ones has been carried out where no significant difference was found. Additionally, greenness profile assessment was accomplished by means of four metric tools. Indeed, the method developed is found to be precise, sensitive, and discriminating to assess the cited drugs for regular analysis.
Keywords:antazoline  dansyl chloride  second derivative  synchronous fluorescence  tetryzoline
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号