首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Determination of tianeptine in human plasma using high-performance liquid chromatography with fluorescence detection
Authors:Tatar Ulu Sevgi
Institution:Department of Analytical Chemistry, Faculty of Pharmacy, Istanbul University, Istanbul 34452, Turkey. sevgitatar@yahoo.com
Abstract:A new, selective and sensitive high-performance liquid chromatography (HPLC) method with fluorimetric detection was developed for the determination of tianeptine (TIA) in human plasma using solid phase extraction (SPE) procedures. The method is based on the derivatization of TIA with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer of pH 8.5 to yield a yellow, fluorescent product. The HPLC separation was achieved on a Phenomenex C(18) column (250 mm x 4.6 mm) using a mobile phase of acetonitrile-10mM orthophosphoric acid (pH 2.5) (77:23, v/v) solvent system at 1 mL/min flow rate. Gabapentin (GA) was used as the internal standard. The fluorometric detector was operated at 458 nm (excitation) and 520 nm (emission). The assay was linear over the concentration range of 5-300 ng/mL. The detection limit (LOD) was found to be 2 ng/mL. The mean recovery was determined to be 88.6%. The proposed method was applied for pharmacokinetic study of 12.5mg TIA in a healthy volunteer.
Keywords:
本文献已被 PubMed 等数据库收录!