首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Improving piezoelectric cell printing accuracy and reliability through neutral buoyancy of suspensions
Authors:Chahal Daljeet  Ahmadi Ali  Cheung Karen C
Institution:Electrical and Computer Engineering, University of British Columbia, 4060 - 2332 Main Mall, Vancouver, BC, Canada V6T 1Z4; telephone: 604-754-5658; fax: 604-822-5949. daljeetc@ece.ubc.ca.
Abstract:The sedimentation and aggregation of cells within inkjet printing systems has been hypothesized to negatively impact printer performance. The purpose of this study was to investigate this influence through the use of neutral buoyancy. Ficoll PM400 was used to create neutrally buoyant MCF‐7 breast cancer cell suspensions, which were ejected using a piezoelectric drop‐on‐demand inkjet printing system. It was found that using a neutrally buoyant suspension greatly increased the reproducibility of consistent cell counts, and eliminated nozzle clogging. Moreover, the use of Ficoll PM400 was shown to not affect cellular viability. This is the first demonstration of such scale and accuracy achieved using a piezoelectric inkjet printing system for cellular dispensing. Biotechnol. Bioeng. 2012; 109: 2932–2940. © 2012 Wiley Periodicals, Inc.
Keywords:cell printing  piezoelectric  inkjet  drug screening  tissue engineering  clogging
本文献已被 PubMed 等数据库收录!