首页 | 本学科首页   官方微博 | 高级检索  
     


A new method for temperature compensation of electrical conductivity using temperature-fold dependency of fresh water
Authors:Shuichi Endoh  Ikuko Tsujii  Munetsugu Kawashima  Yasuaki Okumura
Affiliation:(1) Faculty of Education, Shiga University, 2-5-1 Hiratsu, Otsu 520-0862, Japan;(2) Faculty of Engineering, Osaka Electro-Communication University, Neyagawa, Japan
Abstract:A new method for temperature compensation of electrical conductivity (EC) is proposed. A relationship between temperature and EC was investigated in detail by a simple experiment using natural and artificial fresh water. Results showed that the temperature dependency of EC varied from 0.03 to 0.02, with temperature increasing from 3°C to 35°C. This means that a traditional method for compensating for EC using a constant coefficient is invalid, so that a temperature-fold dependency must be taken into consideration to standardize EC to a common temperature.
Keywords:Electrical conductivity  Temperature compensation  Temperature-fold dependency  Fresh water
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号