Department of Biochemistry, Wallace Laboratories, Division of Carter-Wallace Inc., Half Acre Road, Cranbury, NJ 08512 USA
Abstract:
An isocratic liquid chromatographic method employing one extraction step and a 150 mm × 4.6 mm I.D. Spherisorb ODS2, 3-μm HPLC column using UV-absorbance detection at 210 nm has been developed for the quantitation of felbamate and three felbamate metabolites in 0.100-ml aliquots of rat and dog plasmas. The linear quantitation range in rat plasma is 0.195–200 μg/ml for felbamate; 1.563–200 μg/ml for the p-hydroxy metabolite; 0.391–200 μg/ml for the 2-hydroxy metabolite; and 0.098–200 μg/ml for the monocarbamate metabolite. The linear quantitation range in dog plasma is 0.195–200 μg/ml for felbamate; 0.781–200 μg/ml for the p-hydroxy metabolite; 0.195–200 μg/ml for the 2-hydroxy metabolite; and 0.098–200 μg/ml for the monocarbamate metabolite.