首页 | 本学科首页   官方微博 | 高级检索  
     


Association between Different Indexations of Extravascular Lung Water (EVLW) and PaO2/FiO2: A Two-Center Study in 231 Patients
Authors:Wolfgang Huber  Josef H?llthaler  Tibor Schuster  Andreas Umgelter  Michael Franzen  Bernd Saugel  Colin Cordemans  Roland M. Schmid  Manu L. N. G. Malbrain
Affiliation:1. II. Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, München, Germany.; 2. Institut für Medizinische Epidemiologie und Statistik, Klinikum rechts der Isar der Technischen Universität München, München, Germany.; 3. Department of Intensive Care, Ziekenhuis Netwerk Antwerpen, Antwerpen, Belgium.; Duke University Medical Center, United States of America,
Abstract:

Background

Variability of body weight (BW) and height calls for indexation of volumetric hemodynamic parameters. Extravascular lung water (EVLW) has formerly been indexed to actual BW (BWact) termed EVLW-index (EVLWI). In overweight patients indexation to BWact might inappropriately lower indexed EVLWIact. Several studies suggest indexation of EVLWI to predicted BW (EVLWIpred). However, data regarding association of EVLWIact and EVLWpred to mortality and PaO2/FiO2 are inconsistent. Two recent studies based on biometric database-analyses suggest indexation of EVLWI to height (EVLWIheight). Therefore, our study compared the association of un-indexed EVLW, EVLWIheight, EVLWpred and EVLWIact to PaO2/FiO2 and Oxygenation index (OI = mean airway pressure*FiO2*/PaO2).

Methods

A total of 2119 triplicate transpulmonary thermodilutions (TPTDs; PiCCO; Pulsion Medical-Systems, Germany) were performed in 50 patients from the evaluation, and 181 patients from the validation groups. Correlations of EVLW and EVLWI to PaO2/FiO2, OI and ROC-AUC-analyses regarding PaO2/FiO2<200 mmHg (primary endpoint) and OI>10 were performed.

Results

In the evaluation group, un-indexed EVLW (AUC 0.758; 95%-CI: 0.637-0.880) and EVLWIheight (AUC 0.746; 95%-CI: 0.622-0.869) provided the largest ROC-AUCs regarding PaO2/FiO2<200 mmHg. The AUC for EVLWIpred was smaller (0.713). EVLWIact provided the smallest AUC (0.685). This was confirmed in the validation group: EVLWIheight provided the largest AUC (0.735), EVLWIact (0.710) the smallest. In the merged data-pool, AUC was significantly greater for EVLWIheight (0.729; 95%-CI: 0.674–0.784) compared to all other indexations including EVLWIact (ROC-AUC 0.683, p = 0.007) and EVLWIpred (ROC-AUC 0.707, p = 0.015). The association of EVLW(I) was even stronger to OI compared to PaO2/FiO2. In the merged data-pool, EVLWIheight provided the largest AUC regarding “OI>10” (0.778; 95%-CI: 0.713–0.842) compared to 0.739 (95%-CI: 0.669–0.810) for EVLWIact and 0.756 (95%-CI: 0.688–0.824) for EVLWIpred.

Conclusions

Indexation of EVLW to height (EVLWIheight) improves the association of EVLW(I) to PaO2/FiO2 and OI compared to all other indexations including EVLWIpred and EVLWIact. Also considering two recent biometric database analyses, EVLWI should be indexed to height.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号