首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Preprocessing Significantly Improves the Peptide/Protein Identification Sensitivity of High-resolution Isobarically Labeled Tandem Mass Spectrometry Data
Authors:Quanhu Sheng  Rongxia Li  Jie Dai  Qingrun Li  Zhiduan Su  Yan Guo  Chen Li  Yu Shyr  Rong Zeng
Institution:From the ‡Key Laboratory of Systems Biology, Institute of Biochemistry and Cell Biology, Shanghai Institutes for Biological Science, Chinese Academy of Sciences, Shanghai 200031, China; ;§Center for Quantitative Sciences, Vanderbilt University, Nashville, Tennessee 37232-6848; ;¶Department of Biochemistry and Molecular Biology, University of Southern Denmark, Odense M 5230, Denmark
Abstract:Isobaric labeling techniques coupled with high-resolution mass spectrometry have been widely employed in proteomic workflows requiring relative quantification. For each high-resolution tandem mass spectrum (MS/MS), isobaric labeling techniques can be used not only to quantify the peptide from different samples by reporter ions, but also to identify the peptide it is derived from. Because the ions related to isobaric labeling may act as noise in database searching, the MS/MS spectrum should be preprocessed before peptide or protein identification. In this article, we demonstrate that there are a lot of high-frequency, high-abundance isobaric related ions in the MS/MS spectrum, and removing isobaric related ions combined with deisotoping and deconvolution in MS/MS preprocessing procedures significantly improves the peptide/protein identification sensitivity. The user-friendly software package TurboRaw2MGF (v2.0) has been implemented for converting raw TIC data files to mascot generic format files and can be downloaded for free from https://github.com/shengqh/RCPA.Tools/releases as part of the software suite ProteomicsTools. The data have been deposited to the ProteomeXchange with identifier PXD000994.Mass spectrometry-based proteomics has been widely applied to investigate protein mixtures derived from tissue, cell lysates, or from body fluids (1, 2). Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)1 is the most popular strategy for protein/peptide mixtures analysis in shotgun proteomics (3). Large-scale protein/peptide mixtures are separated by liquid chromatography followed by online detection by tandem mass spectrometry. The capabilities of proteomics rely greatly on the performance of the mass spectrometer. With the improvement of MS technology, proteomics has benefited significantly from the high-resolution and excellent mass accuracy (4). In recent years, based on the higher efficiency of higher energy collision dissociation (HCD), a new “high–high” strategy (high-resolution MS as well as MS/MS(tandem MS)) has been applied instead of the “high–low” strategy (high-resolution MS, i.e. in Orbitrap, and low-resolution MS/MS, i.e. in ion trap) to obtain high quality tandem MS/MS data as well as full MS in shotgun proteomics. Both full MS scans and MS/MS scans can be performed, and the whole cycle time of MS detection is very compatible with the chromatographic time scale (5).High-resolution measurement is one of the most important features in mass spectrometric application. In this high–high strategy, high-resolution and accurate spectra will be achieved in tandem MS/MS scans as well as full MS scans, which makes isotopic peaks distinguishable from one another, thus enabling the easy calculation of precise charge states and monoisotopic mass. During an LC-MS/MS experiment, a multiply charged precursor ion (peptide) is usually isolated and fragmented, and then the multiple charge states of the fragment ions are generated and collected. After full extraction of peak lists from original tandem mass spectra, the commonly used search engines (i.e. Mascot (6), Sequest (7)) have no capability to distinguish isotopic peaks and recognize charge states, so all of the product ions are considered as all charge state hypotheses during the database search for protein identification. These multiple charge states of fragment ions and their isotopic cluster peaks can be incorrectly assigned by the search engine, which can cause false peptide identification. To overcome this issue, data preprocessing of the high-resolution MS/MS spectra is required before submitting them for identification. There are usually two major preprocessing steps used for high-resolution MS/MS data: deisotoping and deconvolution (8, 9). Deisotoping of spectra removes all isotopic peaks except monoisotopic peaks from multi-isotopic peaks. Deconvolution of spectra translates multiply charged ions to singly charged ions and also accumulates the intensity of fragment ions by summing up all the intensities from their multiply charged states. After performing these two data-preprocessing steps, the resulting spectra is simpler and cleaner and allows more precise database searching and accurate bioinformatics analysis.With the capacity to analyze multiple samples simultaneously, stable isotope labeling approaches have been widely used in quantitative proteomics. Stable isotope labeling approaches are categorized as metabolic labeling (SILAC, stable isotope labeling by amino acids in cell culture) and chemical labeling (10, 11). The peptides labeled by the SILAC approach are quantified by precursor ions in full MS spectra, whereas peptides that have been isobarically labeled using chemical means are quantified by reporter ions in MS/MS spectra. There are two similar isobaric chemical labeling methods: (1) isobaric tag for relative and absolute quantification (iTRAQ), and (2) tandem mass tag (TMT) (12, 13). These reagents contain an amino-reactive group that specifically reacts with N-terminal amino groups and epilson-amino groups of lysine residues to label digested peptides in a typical shotgun proteomics experiment. There are four different channels of isobaric tags: TMT two-plex, iTRAQ four-plex, TMT six-plex, and iTRAQ eight-plex (1216). The number before “plex” denotes the number of samples that can be analyzed by the mass spectrum simultaneously. Peptides labeled with different isotopic variants of the tag show identical or similar mass and appear as a single peak in full scans. This single peak may be selected for subsequent MS/MS analysis. In an MS/MS scan, the mass of reporter ions (114 to 117 for iTRAQ four-plex, 113 to 121 for iTRAQ eight-plex, and 126 to 131for TMT six-plex upon CID or HCD activation) are associated with corresponding samples, and the intensities represent the relative abundances of the labeled peptides. Meanwhile, the other ions from the MS/MS spectra can be used for peptide identification. Because of the multiplexing capability, isobaric labeling methods combined with bottom-up proteomics have been widely applied for accurate quantification of proteins on a global scale (14, 1719). Although mostly associated with peptide labeling, these isobaric labeling methods have also been applied at protein level (2023).For the proteomic analysis of isobarically labeled peptides/proteins in “high–high” MS strategy, the common consensus is that accurate reporter ions can contribute to more accurate quantification. However, there is no evidence to show how the ions related to isobaric labeling affect the peptide/protein identification and what preprocessing steps should be taken for high-resolution isobarically labeled MS/MS. To demonstrate the effectiveness and importance of preprocessing, we examined how the combination of preprocessing steps improved peptide/protein sensitivity in database searching. Several combinatorial ways of data-preprocessing were applied for high-throughput data analysis including deisotoping to keep simple monoisotopic mass peaks, deconvolution of ions with multiple charge states, and preservation of top 10 peaks in every 100 Dalton mass range. After systematic analysis of high-resolution isobarically labeled spectra, we further processed the spectra and removed interferential ions that were not related to the peptide. Our results suggested that the preprocessing of isobarically labeled high-resolution tandem mass spectra significantly improved the peptide/protein identification sensitivity.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号