首页 | 本学科首页   官方微博 | 高级检索  
     


Development of magnetic separation and quantum dots labeled immunoassay for the detection of mercury in biological samples
Affiliation:1. Department of Toxicology and Sanitary Chemistry, School of Public Health, Capital Medical University, No. 10 Xitoutiao, You An Men, Beijing 100069, China;2. Beijing Key Laboratory of Environmental Toxicology, Capital Medical University, No. 10 Xitoutiao, You An Men, Beijing 100069, China;3. Medical Experiment and Test Center, Capital Medical University, No. 10 Xitoutiao, You An Men, Beijing 100069, China;1. Department of Physiology and Biophysics, Chicago Medical School, Rosalind Franklin University of Medicine and Science, 3333 Green Bay Road, North Chicago, IL 60064, United States;2. Department of Pediatrics, University of Arkansas for Medical Sciences, Arkansas Children''s Hospital Research Institute, 13 Children''s Way, Little Rock, AR 72202, United States;1. Department of Analytical Chemistry, Faculty of Pharmaceutical Sciences, Toho University, 2-2-1 Miyama, Funabashi-shi, Chiba 274-8510, Japan;2. Optical Instrument Engineering Department, Hitachi High-Tech Science Corporation, 1040, Ichige, Hitachinaka-shi, Ibaraki-ken 312-0033, Japan;3. Medical Systems Development Center, Science & Medical System Design Division, Hitachi High-Technologies Corporation, 882, Ichige, Hitachinaka-shi, Ibaraki-ken 312-8504, Japan
Abstract:A rapid and sensitive immunoassays of mercury (Hg) in biological samples was developed using quantum dots (QDs) and magnetic beads (MBs) as fluorescent and separated probes, respectively. A monoclonal antibody (mAb) that recognizes an Hg detection antigen (BSA-DTPA-Hg) complex was produced by the injection of BALB/c mice with an Hg immunizing antigen (KLH-DTPA-Hg). Then the ascites monoclonal antibodies were purified. The Hg monoclonal antibody (Hg-mAb) is conjugated with MBs to separate Hg from biological samples, and the other antibody, which is associated with QDs, is used to detect the fluorescence. The Hg in biological samples can be quantified using the relationship between the QDs fluorescence intensity and the concentration of Hg in biological samples following magnetic separation. In this method, the detection linear range is 1–1000 ng/mL, and the minimum detection limit is 1 ng/mL. The standard addition recovery rate was 94.70–101.18%. The relative standard deviation values were 2.76–7.56%. Furthermore, the Hg concentration can be detected in less than 30 min, the significant interference of other heavy metals can be avoided, and the simultaneous testing of 96 samples can be performed. These results indicate that the method could be used for rapid monitoring Hg in the body.
Keywords:Mercury  Monoclonal antibody  Magnetic beads  Quantum dots
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号