首页 | 本学科首页   官方微博 | 高级检索  
     


Flow-cytometric analysis of chicken red blood cells.
Authors:D Bloch  N Beaty  C T Fu  E Chin  J Smith  J L Pipkin
Abstract:Flow-cytometric analysis of acriflavin-Feulgen stained chicken erythrocytes shows a complex distribution of amounts of deoxyribonucleic acid fluorescence, the profile consisting of a main peak and a right hand shoulder. This bimodal distribution, an artifact characteristically seen on analysis of flattened cells using orthogonal flow systems, results from fluorescence emission in preferred directions stemming from the combined effects of refractility and orientation of the cells. The shoulder disappears on analysis of lysed erythrocyte ghosts, also on analysis of cells in a medium whose refractive index approximates that the cells. An orientation effect for matrue erythrocytes was indicated by reanalysis of fractions after sorting on the basis of high and low fluorescence or scatter signals. Both fractions gave the original range of values on reanalysis, although some changes in shape of the profile and in the peak positions for the sorted cells were seen. Sodium dodecyl sulfate treatment of stained cells "loosened" the cells' structure, yielding lowered scatter values, and fluorescence values approaching those of the shoulder. The average fluorescence emission of the erythrocytes was lower than that of reticulocytes and lymphocytes. The values of the latter correspond closely, although coincidently, to that the erythrocyte shoulder values. Dual parameter analysis of forward light scatter, and fluorescence, which was detected at 90 degrees to the laser beam, showed the low fluorescence to be accompanied by low scatter signal, and the high fluorescence among the cells with the high scatter signal. The lowered forward scatter signal is due to a wider scattering of light from cells oriented edge-on to the detector, and loss of signal beyond the acceptance angle of the detector. These results suggest that the preferred directions for fluorescence are in the plane of the cells, and the values are dependent on the cells' orientation in the stream. These interpretations were supported by the results of analysis of partially oriented cells. The approaches used and conclusions arrived at are similar to those of Gledhill et al (16), Van Dilla et al (37), in their analysis of fluorescence of flat sperm cells although the affects in the case of the erythrocytes are less extreme.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号