Development of A Loop-Mediated Isothermal Amplification (LAMP) for the Detection of F5 Fimbriae Gene in Enterotoxigenic Escherichia coli (ETEC)
Authors:Kuiyu Jiang  Ying Zhu  Wenxin Liu  Yufei Feng  Lili He  Weikun Guan  Wenxia Hu  Dongfang Shi
Institution:1. Department of Preventive Veterinary Medicine, College of Veterinary Medicine, Northeast Agricultural University, 59 Mucai Street, Xiangfang, Harbin, 150030, Heilongjiang, China
Abstract:The objective of this study was to establish a loop-mediated isothermal amplification (LAMP) method for the detection of F5 fimbriae gene in Enterotoxigenic Escherichia coli. A set of four primers were designed based on the conservative sequence of coding F5 fimbriae. Temperature and time condition, specificity test, and sensitivity test were performed with the DNA of Escherichia coli (F5+). The results showed that the optimal reaction condition for LAMP was achieved at 61 °C for 45 min in a water bath. Ladder-like products were produced with those F5-positive samples by LAMP, while no product was generated with other negative samples. The assay of LAMP had a detection limit equivalent to 72 cfu/tube, which was more sensitive than PCR (7.2 × 102 cfu/tube). The agreement rate between LAMP and PCR was 100 % in detecting simulation samples. Thus, the LAMP assay may be a new method for rapid detection of F5 fimbriae gene of ETEC.
Keywords:
本文献已被 SpringerLink 等数据库收录!