首页 | 本学科首页   官方微博 | 高级检索  
   检索      


96-Well plate assays for measuring collagenase activity using (3)H-acetylated collagen.
Authors:P J Koshy  A D Rowan  P F Life  T E Cawston
Institution:School of Clinical and Medical Sciences, University of Newcastle upon Tyne, Newcastle upon Tyne, NE2 4HH, United Kingdom.
Abstract:We describe two alternative assays for measuring collagenolytic activity using (3)H-acetylated collagen. Both assays have been developed for the 96-well plate format and measure the amount of radiolabeled collagen fragments released into the supernatant from an insoluble (3)H-acetylated collagen fibril preparation. The first method separates digested solubilized fragments from the intact fibril by sedimentation of the undigested collagen by centrifugation. The second method achieves this separation by filtration of the supernatant through the membrane of a 96-well filtration plate which retains the undigested collagen fibril. Both methods give linear dose- and time-dependent responses of collagenase activity > or = 70% of total collagen lysis. In addition, both assays can be simply modified to measure tissue inhibitors of metalloproteinases (TIMPs) inhibitory activity, which is also linear between 20 and 75% of total collagen lysis with the amount of TIMP added.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号