首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Probing the stability of S-layer-supported planar lipid membranes
Authors:Bernhard Schuster  Uwe B Sleytr  Anke Diederich  Günther Bähr  Mathias Winterhalter
Institution:Center for Ultrastructure Research and Ludwig-Boltzmann-Institute for Molecular Nanotechnology, Universit?t für Bodenkultur Wien, Gregor-Mendel-Strasse 33, A-1180 Vienna, Austria e-mail: bschuste@edv1.boku.ac.at, AT
Department of Biophysical Chemistry, Biozentrum, University of Basel, Klingelbergstrasse 70, CH-4056 Basel, Switzerland, CH
Abstract:Isolated protein subunits of the crystalline bacterial cell surface layer (S-layer) of Bacillus coagulans E38-66 have been recrystallized on one side of planar black lipid membranes (BLMs) and their influence on the electrical properties, rupture kinetics and mechanical stability of the BLM was investigated. The effect on the boundary potential, the capacitance or the conductance of the membrane was negligible whereas the mechanical properties were considerably changed. The mechanical stability was characterized by applying voltage pulses or ramps to induce irreversible rupture. The amplitude of the voltage pulse leading to rupture allows conclusions on the ability of membranes to resist external forces. Surprisingly, these amplitudes were significantly lower for composite S-layer/lipid membranes compared to undecorated BLMs. In contrast, the delay time between the voltage pulse and the appearance of the initial defect was found to be drastically longer for the S-layer-supported lipid bilayer. Furthermore, the kinetics of the rupture process was recorded. Undecorated membranes show a fast linear increase of the pore conductance in time, indicating an inertia-limited defect growth. The attachment of an S-layer causes a slow exponential increase in the conductance during rupture, indicating a viscosity-determined widening of the pore. In addition, the mechanical properties on a longer time scale were investigated by applying a hydrostatic pressure across the BLMs. This causes the BLM to bulge, as monitored by an increase in capacitance. Compared to undecorated BLMs, a significantly higher pressure gradient has to be applied on the S-layer face of the composite BLMs to observe any change in capacitance. Received: 4 May 1999 / Revised version: 1 July 1999 / Accepted: 1 July 1999
Keywords:Crystalline bacterial surface layer  S-layer  Lipid membrane  Irreversible breakdown
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号