首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Ultra Rapid-Acting Inhaled Insulin Improves Glucose Control in Patients With Type 2 Diabetes Mellitus
Institution:1. MODEL Clinical Research, Endocrinology, Baltimore, Maryland;2. Emeritus, Endocrinology, Diabetes and Metabolism, Cleveland Clinic, Cleveland, Ohio;3. Central Michigan University, Mount Pleasant, Michigan;4. University of Colorado Anschutz Medical Campus, Pediatrics, Aurora, Colorado;5. Colorado School of Public Health, Department of Biostatistics and Informatics, Aurora, Colorado
Abstract:ObjectiveTo determine whether the use of an inhaled insulin would improve HbA1c.MethodsThis study was performed in 20 type 2 diabetes mellitus (T2DM) participants with HbA1c values ≥7.5 (58) to ≤11.5% (102 mmol/mol) on a variety of glucose-lowering regimens. Prandial Technosphere insulin (TI) was rapidly titrated based on a treatment algorithm using postprandial blood glucose to calculate premeal doses. A 2-week baseline period was followed by 12 weeks of active treatment with TI. The primary outcome was change in HbA1c. Secondary outcomes included glucose time in range (time in range: 70-180 mg/dL) obtained by a blinded continuous glucose monitoring during the baseline period and at the end of 12 weeks. Goals were to assess how to rapidly and safely initiate TI intensification, determine dosing requirements, and establish an effective dose range in uncontrolled T2DM.ResultsMean HbA1c decreased by ?1.6% (?17 mmol/mol) from 9.0% (75 mmol/mol) at baseline to 7.4% (57 mmol/mol) at 12 weeks (P < .0001). Mean time in range increased from 42.2% to 65.7% (P < .0002). Mean prandial doses of TI were 18 or 19 units for all meals. Time below range was 1.1% baseline and 2.6% post treatment (P = .01).ConclusionTreatment with inhaled TI dosed using a simple algorithm improved glycemic control measured by both HbA1c and time in range, with low rates of hypoglycemia. These data add significantly to understanding TI in the management of T2DM patients for whom prandial insulin is a consideration.
Keywords:diabetes  hyperglycemia  insulin  BG"}  {"#name":"keyword"  "$":{"id":"kwrd0030"}  "$$":[{"#name":"text"  "_":"blood glucose  CGM"}  {"#name":"keyword"  "$":{"id":"kwrd0040"}  "$$":[{"#name":"text"  "_":"continuous glucose monitoring  CGMS"}  {"#name":"keyword"  "$":{"id":"kwrd0035w"}  "$$":[{"#name":"text"  "_":"continuous glucose monitoring system  GLP"}  {"#name":"keyword"  "$":{"id":"kwrd0050"}  "$$":[{"#name":"text"  "_":"glucagon-like peptide  SGLT2"}  {"#name":"keyword"  "$":{"id":"kwrd0035x"}  "$$":[{"#name":"text"  "_":"sodium-glucose cotransporter 2  T2DM"}  {"#name":"keyword"  "$":{"id":"kwrd0060"}  "$$":[{"#name":"text"  "_":"type 2 diabetes mellitus  TBR"}  {"#name":"keyword"  "$":{"id":"kwrd0070"}  "$$":[{"#name":"text"  "_":"time below range  TI"}  {"#name":"keyword"  "$":{"id":"kwrd0080"}  "$$":[{"#name":"text"  "_":"Technosphere insulin  TIR"}  {"#name":"keyword"  "$":{"id":"kwrd0090"}  "$$":[{"#name":"text"  "_":"time in range
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号