Flash Glucose Monitoring Compared to Capillary Glucose Levels in Patients With Diabetic Ketoacidosis: Potential Clinical Applications
Affiliation:1. South Australia Health, Endocrine Unit, Adelaide, Australia;2. School of Medicine, The University of Notre Dame, Sydney, Australia;3. Royal Adelaide Hospital, The University of Adelaide, Adelaide, Australia
Abstract:ObjectiveFrequent, finger-prick capillary blood glucose measurement is standard care, used to drive insulin infusion rates for inpatients being resuscitated from diabetic ketoacidosis (DKA). Over recent years there has been a shift toward continuous interstitial glucose monitoring, allowing monitoring of glucose without repeated invasive testing. While continuous interstitial glucose monitoring has been safely and reliably utilized in the outpatient setting, it has yet to be studied in acutely unwell patients with DKA. The aim of this study, allowing for physiologically lower interstitial compared to capillary glucose, was to determine if interstitial flash glucose monitoring (FGM) would lead to insulin infusion rates that were similar to capillary blood glucose (CapBG) in DKA.MethodsIn this study, 10 patients with diabetes mellitus, assessed to be in DKA, were enrolled. At the same time as standard DKA management commencement, simultaneous FGM measurements were obtained. Duplicate paired glucose readings were then analyzed for agreement.ResultsActual (CapBG-driven) and predicted (FGM determined) insulin infusion rates were similar. Minor differences in predicted insulin infusion rates were noted in 2/10 patients at higher glucose concentrations, which may relate to the lag in change in glucose in the interstitial space.ConclusionBased on our results, a trial of clinical outcomes in patients with DKA treated with insulin infusion rates driven by CapBG versus subcutaneous FGM appears justified. The FGM method of testing may improve patient comfort, obviate fatigue, improve staff time and direct patient contact, and potentially facilitate rapid discharge.
Keywords:Capillary  diabetes mellitus  flash  glucose  ketoacidosis  monitoring  adjFMG"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0045"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  adjusted flash glucose monitoring  CapBG"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0055"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  capillary blood glucose  CGM"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0065"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  continuous glucose monitoring  DKA"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0075"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  diabetic ketoacidosis  FGM"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0085"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  flash glucose monitoring  IQR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0095"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  interquartile range
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号