首页 | 本学科首页   官方微博 | 高级检索  
   检索      


The refractometer index as a correction factor for urinary estradiol in rhesus females
Authors:J K Thibodeaux  C A Anzalone  S A Voelkel  J D Roussel  L L Goodeaux
Institution:Department of Dairy Science, Louisiana State University, Baton Rouge.
Abstract:Refractometer indexes were standardized and found to be highly correlated (r = 0.831) to actual creatinine levels. Urinary estradiol corrected by creatinine levels and refractometer indexes were found to be highly correlated (r = 0.857). Predicted ovulation was the same day in 86% of the ovulatory cycles predicted by creatinine and refractometer corrected estradiol levels. Refractometer indexes may be used in place of creatinine levels to correct for urine concentration fluctuations when predicting ovulation in the rhesus female.
Keywords:Creatinine  Urinary hormones  Urine concentration  Ovulation  Monitoring ovarian function