首页 | 本学科首页   官方微博 | 高级检索  
     


The Strain at Bone-Implant Interface Determines the Effect of Spinopelvic Reconstruction following Total Sacrectomy: A Strain Gauge Analysis in Various Spinopelvic Constructs
Authors:Yan Yu  Rui Zhu  Zhi-Li Zeng  Yong-Wei Jia  Zhou-Rui Wu  Yi-Long Ren  Bo Chen  Zu-Quan Ding  Li-Ming Cheng
Affiliation:1. Department of Spine Surgery, Tongji Hospital, Tongji University School of Medicine, Shanghai, China.; 2. Julius Wolff Institut, Charité-Universitätsmedizin Berlin, Berlin, Germany.; 3. School of Life Science and Technology, Tongji University, Shanghai, China.; 4. Institute of Orthopaedics and Traumatology, Shanghai, China.; Bascom Palmer Eye Institute, University of Miami School of Medicine, United States of America,
Abstract:

Purpose

There is still some controversy regarding the optimal biomechanical concept for spinopelvic stabilization following total sacrectomy for malignancy. Strains at specific anatomical sites at pelvis/sacrum and implants interfaces have been poorly investigated. Herein, we compared and analyzed the strains applied at key points at the bone-implant interface in four different spinopelvic constructs following total sacrectomy; consequently, we defined a balanced architecture for spinopelvic fusion in that situation.

Methods

Six human cadaveric specimens, from second lumbar vertebra to proximal femur, were used to compare the partial strains at specific sites in a total sacrectomy model. Test constructs included: (1) intact pelvis (control), (2) sacral-rod reconstruction (SRR), (3) bilateral fibular flap reconstruction (BFFR), (4) four-rods reconstruction (FRR), and (5) improved compound reconstruction (ICR). Strains were measured by bonded strain gauges onto the surface of three specific sites (pubic rami, arcuate lines, and posterior spinal rods) under a 500 N axial load.

Results

ICR caused lower strains at specific sites and, moreover, on stress distribution and symmetry, compared to the other three constructs. Strains at pubic rami and arcuate lines following BFFR were lower than those following SRR, but higher at the posterior spinal rod construct. The different modes of strain distribution reflected different patient’s parameter-related conditions. FRR model showed the highest strains at all sites because of the lack of an anterior bracing frame.

Conclusions

The findings of this investigation suggest that both anterior bracing frame and the four-rods load dispersion provide significant load sharing. Additionally, these two constructs decrease the peak strains at bone-implant interface, thus determining the theoretical surgical technique to achieve optimal stress dispersion and balance for spinopelvic reconstruction in early postoperative period following total sacrectomy.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号