首页 | 本学科首页   官方微博 | 高级检索  
     


Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI
Authors:Yan Li  Li Wang  Shi-Hua Zhao  Zuo-Xiang He  Dao-Yu Wang  Feng Guo  Wei Fang  Min-Fu Yang
Affiliation:1. Department of Nuclear Medicine, Cardiovascular Institute and Fu Wai Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China.; 2. Department of Radiology, Cardiovascular Institute and Fu Wai Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China.; 3. Department of Nuclear Medicine, Chaoyang Hospital, Capital Medical University, Beijing, China.; Washington Hospital Center, United States of America,
Abstract:

Purpose

Ventricular function is a powerful predictor of survival in patients with heart failure (HF). However, studies characterizing gated F-18 FDG PET for the assessment of the cardiac function are rare. The aim of this study was to prospectively compare gated F-18 FDG PET and cardiac MRI for the assessment of ventricular volume and ejection fraction (EF) in patients with HF.

Methods

Eighty-nine patients with diagnosed HF who underwent both gated F-18 FDG PET/CT and cardiac MRI within 3 days were included in the analysis. Left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), and EF were obtained from gated F-18 FDG PET/CT using the Quantitative Gated SPECT (QGS) and 4D-MSPECT software.

Results

LV EDV and LV ESV measured by QGS were significantly lower than those measured by cardiac MRI (both P<0.0001). In contrast, the corresponding values for LV EDV for 4D-MSPECT were comparable, and LV ESV was underestimated with borderline significance compared with cardiac MRI (P = 0.047). LV EF measured by QGS and cardiac MRI showed no significant differences, whereas the corresponding values for 4D-MSPECT were lower than for cardiac MRI (P<0.0001). The correlations of LV EDV, LV ESV, and LV EF between gated F-18 FDG PET/CT and cardiac MRI were excellent for both QGS (r = 0.92, 0.92, and 0.76, respectively) and 4D-MSPECT (r = 0.93, 0.94, and 0.75, respectively). However, Bland-Altman analysis revealed a significant systemic error, where LV EDV (−27.9±37.0 mL) and ESV (−18.6±33.8 mL) were underestimated by QGS.

Conclusion

Despite the observation that gated F-18 FDG PET/CT were well correlated with cardiac MRI for assessing LV function, variation was observed between the two imaging modalities, and so these imaging techniques should not be used interchangeably.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号