首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Distribution of labelled anti-tenascin antibodies and fragments after injection into intact or partly resected C6-gliomas in rats
Authors:Claudia Maria Goetz  Walter Rachinger  Markus Decker  Franz-Josef Gildehaus  Susanne Stocker  Gundram Jung  Klaus Tatsch  Jörg-Christian Tonn  Hans-Jürgen Reulen
Institution:(1) Department of Neurosurgery, Ludwig-Maximilians-Universität, Munich, Germany;(2) Department of Nuclear Medicine, Ludwig-Maximilians-Universität, Munich, Germany;(3) Laser Research Laboratory, Ludwig-Maximilians-Universität, Munich, Germany;(4) Department of Immunology, Eberhard-Karls-Universität, Tübingen, Germany
Abstract:Introduction: For treatment of malignant glioma, radioimmunotherapy has become a valuable alternative for more than 2 decades. Surprisingly, very little is known about the distribution of intralesionally administered labelled antibodies or fragments. We investigated the migration of labelled antibodies and antibody fragments injected into intact and partly resected C6-glioma in rats at different times after injection. Materials and methods: Nine days after induction of a C6-glioma, 5 mgrl of 125I-labelled murine anti-tenascin antibodies (n=31) or 125I-labelled fragments of anti-tenascin antibodies (n=32) was injected slowly into the tumour (group I). In group II the tumour was subtotally resected 9 days after induction of the C6-glioma, and 24 h later the labelled antibodies (n=30) or fragments (n=12) were injected into the resection cavity. At 6, 24 or 48 h after the injection, animals were sacrificed, and brains removed. Distribution of labelled antibodies and fragments was determined by superimposing autoradiographs onto frozen sections and HE-stained neighbouring sections using a digital image analysing system. Results: After injection into intact C6-glioma, labelled antibodies covered a maximum distance of 3.2 ± 1.0, 4.1 ± 1.9 and 4.8 ± 0.9 mm after 6, 24 and 48 h, respectively; while labelled fragments were found at a distance of 6.7 mm (±1.1) after 24 h and 5.8 mm (±0.9) after 48 h (significant in univariate analysis). Following partial tumour resection, the respective distances at 24 h were 3 ± 0.4 mm for anti-tenascin antibodies and 3.4 ± 0.3 mm for Fab fragments. Conclusion: After injection into C6-glioma, labelled fragments are able to cover a greater distance than labelled antibodies. Injection of antibodies and fragments 1 day after tumour resection results in reduced velocity of both antibodies and fragments.
Keywords:C6-glioma  Distribution  Fragments  Radioimmunotherapy  Tenascin
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号