Correlating on-line monitoring parameters, pH, DO and ORP with nutrient removal in an intermittent cyclic process bioreactor system |
| |
Authors: | Tanwar Pankaj Nandy Tapas Ukey Pallavi Manekar Pravin |
| |
Affiliation: | National Environmental Engineering Research Institute, Wastewater Technology Division, Nehru Marg, Nagpur, Maharashtra 440 020, India. |
| |
Abstract: | The paper presents the study correlating the profile of on-line monitoring parameters and nutrient removal in an intermittent cyclic process bioreactor (ICPBR) system, thereby utilizing the parameters as operational tool. A laboratory scale ICPBR was employed to treat low C/N ratio domestic wastewater from a township. The study was conducted for correlating biological nutrient removal and on-line monitored parameters pH, dissolved oxygen (DO) and oxidation-reduction potential (ORP). The results revealed that pH, DO and ORP related with the dynamic behavior of nutrient concentration (NH4-N, NO3-N, and PO4-P) during treatment in an ICPBR system. The variation in pH and ORP of the reactor liquor correlate to conversion of ammonia (NH4-N) and nitrate (NO3-N) concentrations, respectively. As the bioconversion of ammonia nitrogen and phosphorus are related to the varying profile of the on-line monitored parameters, the profiles could possibly be used as onsite process control parameters. |
| |
Keywords: | Cyclic bio-reactor On-line monitoring Nutrient removal Correlation |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|