首页 | 本学科首页   官方微博 | 高级检索  
     

采用OCT系统对组织光学通透的研究
引用本文:孙惠霞,李鹏,何永红,马辉.采用OCT系统对组织光学通透的研究[J].激光生物学报,2007,16(5):521-526.
作者姓名:孙惠霞  李鹏  何永红  马辉
作者单位:清华大学深圳研究生院光学检测与成像实验室,深圳,518055;清华大学深圳研究生院光学检测与成像实验室,深圳,518055;清华大学物理系原子分子纳米科学教育部重点实验室,北京,100084
基金项目:国家自然科学基金面上项目(60578003),国家“973”计划资助项目(2006CB70570)
摘    要:组织通透方法采用高折射率化学试剂对生物组织进行渗透,改变组织的光学均匀性,可以有效地改善光学成像的穿透深度,受到生物医学光学研究领域的重视。利用光学相干层析成像技术,测量通透过程中不同测量深度下组织的散射特征的变化。通过采用系统信号对数的梯度值近似地表征光学散射系数,研究了通透过程中组织的散射特征随渗透时间和测量深度的动态关系。实验证明了组织通透可以有效地增加光子的穿透深度,并改善成像质量。研究发现:不同测量深度处组织的散射系数及其变化幅度、变化过程和变化趋势等均存在一定的差异性,并与组织的微观结构、其通透效果,化学试剂在组织中的渗透行为等有密切关系,有助于组织通透过程的理解,并为组织通透机制提供可能的实验依据。

关 键 词:组织通透  光学相干层析  散射系数
文章编号:1007-7146(2007)05-0521-06
收稿时间:2006-12-20
修稿时间:2007-03-15

A Study of the Optical Clearing by OCT
SUN Hui-xia,LI Peng,HE Yong-hong,MA Hui.A Study of the Optical Clearing by OCT[J].ACTA Laser Biology Sinica,2007,16(5):521-526.
Authors:SUN Hui-xia  LI Peng  HE Yong-hong  MA Hui
Affiliation:1. Laboratory of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China; 2. Key Laboratory for Molecular and Nanosciences of Education Ministry Department of Physics, Tsinghua University, Beijing 100084, China
Abstract:Optical clearing can effectively control the optical properties of in tissue using the optical immersing technique by hyperosmotic agents and be paid more and more attention in the biomedical and optical field.This mothed could reduce the number of the multiple scattered photons,increase the depth of the optical imaging,and get a better contrast grade of images.We measured the change of the optical properties of the tissue of the different depth during the optical clearing process using optical coherence tomography(OCT).We applied the gradient of the OCT signal algorithm to analyze the temporal and spatial distribution of the scattering coefficient during the clearing process.It was demonstrated experimentally that optical clearing could effectively improve the OCT imaging depth.During the process of the optical clearing,the scattering coefficient,the range and the time and the trend of the change of the scattering coefficient changed with the different depth,which was related to the tissue microstructure,the clearing effect due to the microstructure and the diffuse process of the agent.The results could be used to understand the process and the mechanism of the optical clearing.
Keywords:optical clearing  optical coherence tomography(OCT)  scattering coefficient
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号