首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Bacteriophage-based biosorbents coupled with bioluminescent ATP assay for rapid concentration and detection of Escherichia coli
Authors:O Minikh  M Tolba  MW Griffiths
Institution:a Canadian Research Institute for Food Safety, University of Guelph, 43 McGilvray St., Guelph, Ontario, N1G 2W1 Canada
b Department of Chemical Enzymology, Lomonosov Moscow State University, 1/3, Leninskiy Gory, 119991 Moscow, Russia
Abstract:Wild type T4 bacteriophage and recombinant T4 bacteriophages displaying biotin binding peptide (BCCP) and cellulose binding module (CBM) on their heads were immobilized on nano-aluminum fiber-based filter (Disruptor™), streptavidin magnetic beads and microcrystalline cellulose, respectively. Infectivity of the immobilized phages was investigated by monitoring the phage-mediated growth inhibition of bioluminescent E. coli B and cell lysis using bioluminescent ATP assay. The results showed that phage immobilization resulted in a partial loss of infectivity as compared with the free phage. Nevertheless, the use of a biosorbent based on T4 bacteriophage immobilized on Disruptor™ filter coupled with a bioluminescent ATP assay allowed simultaneous concentration and detection of as low as 6 × 103 cfu/mL of E. coli in the sample within 2 h with high accuracy (CV = 1-5% in log scale). Excess of interfering microflora at levels 60-fold greater than the target organism did not affect the results when bacteriophage was immobilized on the filter prior to concentration of bacterial cells.
Keywords:Immobilized T4 bacteriophage  Escherichia coli  ATP bioluminescence assay
本文献已被 ScienceDirect 等数据库收录!